PUBLISHED LOT DOCUMENTATION
BPC-157
LOT BP10A
Tested Aug 11, 2026 · Certificate COA-2026-TO3TS1
This laboratory documentation does not indicate product availability or commercial release.
- Product
- BPC-157
- ILS lot number
- BP10A
- Document type
- ILS laboratory certificate
- Testing laboratory
- ILS Laboratories
- Test date
- Aug 11, 2026
- Laboratory result
- PASS
- Reported HPLC purity (per ILS)
- 99.82%
- Laboratory certificate
- COA-2026-TO3TS1
- Peptide Purity (HPLC) method
- RP-HPLC area normalization at 214 nm
- Net Peptide Content
- 10.26 mg N/A
- Identity (ID)
- Confirmed PASS
- Identity (ID) method
- HPLC. Identification by chromatographic retention time comparison with a reference standard.
- Arsenic (As)
- 0.398 ppm PASS
- Arsenic (As) method
- ICP-MS per USP ⟨233⟩ methodology
- Cadmium (Cd)
- 0.418 ppm PASS
- Cadmium (Cd) method
- ICP-MS per USP ⟨233⟩ methodology
- Chromium (Cr)
- 0.596 ppm PASS
- Chromium (Cr) method
- ICP-MS per USP ⟨233⟩ methodology
- Mercury (Hg)
- 0.64 ppm PASS
- Mercury (Hg) method
- ICP-MS per USP ⟨233⟩ methodology
- Lead (Pb)
- 0.55 ppm PASS
- Lead (Pb) method
- ICP-MS per USP ⟨233⟩ methodology
- Sterility (PCR)
- No Growth PASS
- Sterility (PCR) method
- PCR (Polymerase Chain Reaction) method
- Endotoxin (USP <85>)
- 0.034 EU/mL Reported
- Endotoxin (USP <85>) method
- USP ⟨85⟩ kinetic chromogenic method
- Fentanyl Screen
- Confirmed Fentanyl Free
Integrity details
Ohana's archived copy was recorded on September 8, 2026.
This SHA-256 value identifies the exact archived PDF file.
60fed633c24801941c51c8fd5bf7ee2a8fb7332fb971d43e472ff232f89c2da9