PUBLISHED LOT DOCUMENTATION
PT-141
LOT PT10A
Tested Aug 12, 2026 · Certificate COA-2026-HIQZOP
This laboratory documentation does not indicate product availability or commercial release.
- Product
- PT-141
- ILS lot number
- PT10A
- Document type
- ILS laboratory certificate
- Testing laboratory
- ILS Laboratories
- Test date
- Aug 12, 2026
- Laboratory result
- PASS
- Reported HPLC purity (per ILS)
- 98.40%
- Laboratory certificate
- COA-2026-HIQZOP
- Peptide Purity (HPLC) method
- RP-HPLC area normalization at 214 nm
- Net Peptide Content
- 10.11 mg N/A
- Identity (ID)
- Confirmed PASS
- Identity (ID) method
- HPLC. Identification by chromatographic retention time comparison with a reference standard.
- Arsenic (As)
- 0.388 ppm PASS
- Arsenic (As) method
- ICP-MS per USP ⟨233⟩ methodology
- Cadmium (Cd)
- 0.43 ppm PASS
- Cadmium (Cd) method
- ICP-MS per USP ⟨233⟩ methodology
- Chromium (Cr)
- 0.698 ppm PASS
- Chromium (Cr) method
- ICP-MS per USP ⟨233⟩ methodology
- Mercury (Hg)
- 0.658 ppm PASS
- Mercury (Hg) method
- ICP-MS per USP ⟨233⟩ methodology
- Lead (Pb)
- 0.558 ppm PASS
- Lead (Pb) method
- ICP-MS per USP ⟨233⟩ methodology
- Sterility (PCR)
- No Growth PASS
- Sterility (PCR) method
- PCR (Polymerase Chain Reaction) method
- Endotoxin (USP <85>)
- 0.028 EU/mL Reported
- Endotoxin (USP <85>) method
- USP ⟨85⟩ kinetic chromogenic method
- Fentanyl Screen
- Confirmed Fentanyl Free